Ericsson · Boards, Cards & Modules
Ericsson GEP, GED and blade server boards
These are the processing, switching and control boards that populate Ericsson's blade and telecom server platforms — the hardware behind core network functions, AXE exchanges and the SmartEdge and SSR routing families rather than anything on a tower. Enquiries here tend to come from operators maintaining core sites where a single board failure takes out capacity, and where the platform is old enough that the manufacturer's replacement path is a project rather than a part number.
How to read these part numbers
Ericsson identifies these boards by product number rather than by the name printed on the ejector, and both appear in this table. ROJ prefixes plug-in board assemblies and ROA prefixes interface and line boards. The board name describes function — GEP is a general-purpose processor blade, GED a disk or storage board, CPUB a CPU board with its core count in the suffix, CMXB and SCXB switching and control boards, ENET an Ethernet interface. Suffixes such as R1A, R2B or R3C are revision states, and a later revision is normally backward compatible against the same subrack.
Catalogue
Equipment reference
| Part Number | Model / Designation | Compatibility | Band / Interface | Condition | Lead Time | Quote |
|---|---|---|---|---|---|---|
| 1/ROJ208459/1 R4+ | GARP2-TRH B | On enquiry | On enquiry | On enquiry | On enquiry | |
| 2/ROJ208459/1 R4+ | GARP2-GPH B | On enquiry | On enquiry | On enquiry | On enquiry | |
| 2/ROJ208459/1 R4F | GARP2-GPH B | On enquiry | On enquiry | On enquiry | On enquiry | |
| 70120001 | RF Absorbing base 260x30 | On enquiry | On enquiry | On enquiry | On enquiry | |
| 70120002 | RF Absorbing base 360x30 | On enquiry | On enquiry | On enquiry | On enquiry | |
| 78210623V43 | Twin Diplxer 78210623V43 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BFD101078/1 | CN510 R2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BFL901009 FOR SUP /4 | RBS6601 for SUP/4 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BFL901009/4 R1E | SUP 6601 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BFL901009/4 R2A | SUP 6601 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BGM1361006/2 R2A | SCU 02 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BKL90101/1 | FCB | On enquiry | Control board | On enquiry | On enquiry | |
| BMG980347/3 R2+ | PDU-HC | On enquiry | On enquiry | On enquiry | On enquiry | |
| BML161174/1 R3H | PSU AC 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| BML901367/1 | POWER 6302 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ENET 10/100 | On enquiry | On enquiry | On enquiry | On enquiry | ||
| KDU127161/3 | DUW 30 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU127161/3 R4+ | DUW 30 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU127161/3 R4F | DUW 30 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU127174/3 R1+ | DUW 31 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU127174/4 R2+ | DUW 41 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU1370093/11 | RAN Processor 6651 Processor Unit | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137533/4 R1+ | DUL 20 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137533/4 R2+ | DUL 20 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137596/2 | SIU-02 with Fan | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137596/2 R1+ | SIU-02 with Fan | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137596/2 R2+ | SIU-02 with Fan | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137597/1 R1G | DUG 10 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137624/3 R1C | DUS 31 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137624/3 R3+ | DUS 31 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137624/31 R4+ | DUS 31 02 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KDU137624/31 R5+ | DUS 31 02 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KFE1011162/2 R1+ | PFU 02 01 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11862/2 R2A | RUS 01 B8 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11865/2 | RUS01B3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11865/2 R1+ | RUS 01 B3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11865/2 R3+ | RUS 01 B3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11875/1 R2+ | RUS 01 B3(1800) | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11875/1 R3+ | RUS 01 B1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11890/1 R1C | RUS 01 B20 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11890/2 R1+ | RUS 01 B20 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11890/2 R1E | RUS 01 B20 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11890/2 R1F | RUS 01 B20 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC11893/3 R1A | AIR 11 B20A B8P | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC1311002/2 | DTRU 900 Edge | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC161118/1 R4+ | ER DRU18-03 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC161197/1 R1F | RUG 11 B3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC161197/1 R1G | RUG 11 B3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC161263/1 R1+ | RUS 02 B0 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRC161296/1 R1+ | RUS 02 B1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRF901154/2 R2+ | KRF901154/2 R2+ | On enquiry | On enquiry | On enquiry | On enquiry | |
| KRY112197/2 R1A | DDBTMA 18/21 | On enquiry | On enquiry | On enquiry | On enquiry | |
| NFS89973/5 | ECM 03 05 | On enquiry | Electronic control unit | On enquiry | On enquiry | |
| NTB10129/1 | NTB10129/1; Connector kit SUP 6601 V2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| NTM1012589/1 R1A | SET OF MATERIALS/6601 | On enquiry | On enquiry | On enquiry | On enquiry | |
| RDB10160/1 | PATC8MPOLCMAR01G | On enquiry | On enquiry | On enquiry | On enquiry | |
| RDH10247/3 | RTXM192-466-C24 | On enquiry | On enquiry | On enquiry | On enquiry | |
| RDH10265/1 | OSFP+ 10GBASE-SR&CPRI | On enquiry | On enquiry | On enquiry | On enquiry | |
| RNT44732/02 | 2 WAY PLUG CONECTOR, 14-2S | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROA128183/1 | ENET 10GE | On enquiry | R1B | On enquiry | On enquiry | |
| ROA1283183/1 | ENET 10GE | On enquiry | R1B | On enquiry | On enquiry | |
| ROA1283186/1 | 60x1 Fast Eth TX | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROA1283203/1 | XCRP3 | On enquiry | SNRPEDOBAA | On enquiry | On enquiry | |
| ROA1283204/1 | Cross Connect | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROA1283204/1 | XCRP4 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROA1283411/1 | On enquiry | On enquiry | 10x1 Gbit Eth | On enquiry | On enquiry | |
| ROF1371794/3 R3 | BISS | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192106/51 | GPB 51 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192106/64 | GPB | On enquiry | R1D | On enquiry | On enquiry | |
| ROJ1192106/65 | GPB | On enquiry | R1E | On enquiry | On enquiry | |
| ROJ1192106/75 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192109/3 | SXB3 | On enquiry | R1D | On enquiry | On enquiry | |
| ROJ1192163/1 | ET-MC1 | On enquiry | R5F | On enquiry | On enquiry | |
| ROJ1192201/2 | MSB3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192254/7 | TX6HS-03 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192291/1 | ET-MF4 | On enquiry | R1A | On enquiry | On enquiry | |
| ROJ1192315/2 | 3G ET-MFX 11 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192325/1 R1+ | SAU3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ1192331/1 | MSB AMC Carrier | On enquiry | R2B | On enquiry | On enquiry | |
| ROJ1192333/1 | AMC DSP | On enquiry | R1E | On enquiry | On enquiry | |
| ROJ1192334/3 | SCB-TF | On enquiry | R1D | On enquiry | On enquiry | |
| ROJ1192345/1 | ET-IPG | On enquiry | Printed board assembly, 1Gb/s, 4 port | On enquiry | On enquiry | |
| ROJ1192403/1 | SPB | On enquiry | R1D/A | On enquiry | On enquiry | |
| ROJ1192508/1 | PFU 1101 | On enquiry | Board | On enquiry | On enquiry | |
| ROJ1192509/1 | PFU 1201 | On enquiry | Board | On enquiry | On enquiry | |
| ROJ1192519/1 | PFU 1301 | On enquiry | Printed board assembly | On enquiry | On enquiry | |
| ROJ20406/1 | DLHB | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ20406/1 R1+ | DLHB | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ20416/7 R1+ | RPP | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ20443/2 R1+ | RPG3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ204507/1 R6+ | RP4-H | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ2081301/2 | MMU2 B | On enquiry | R1B, AXE-810 | On enquiry | On enquiry | |
| ROJ2081311/1 | MMU3 A | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ2081317/1 | MMU3 B | On enquiry | R2A | On enquiry | On enquiry | |
| ROJ2081323/1 | On enquiry | On enquiry | Printed board assembly | On enquiry | On enquiry | |
| ROJ208221/1 R3 | TAU-C | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208304/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208304/2 R1+ | XDB-2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208304/2 R1F | XDB-2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208306/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208306/2 R1+ | PET155-1-O-2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208312/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208315/1 | CDB | On enquiry | R1F | On enquiry | On enquiry | |
| ROJ208315/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208315/1 R1+ | CDB | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208315/1 R1F | CDB | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208316/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208323/1 | SCB-RP | On enquiry | R2J | On enquiry | On enquiry | |
| ROJ208323/4 | SCB-RP | On enquiry | R3B | On enquiry | On enquiry | |
| ROJ208351/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208368/10 | MXB5-LE PIU | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208386/2 | SCXB2 | On enquiry | R3A | On enquiry | On enquiry | |
| ROJ208392/1 | CMXB3 EGEM2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208392/1 R7+ | CMXB3 EGEM | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208394/1 | EPB1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208394/1 R1+ | EPB1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208394/2 | EPB1 | On enquiry | 1500 MHz | On enquiry | On enquiry | |
| ROJ208395/1 | SCXB3 | On enquiry | R7C | On enquiry | On enquiry | |
| ROJ208395/1 R5+ | SCXB3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208395/1 R6+ | SCXB3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208410/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208436/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208459/1 | GARP-2 | On enquiry | R4B | On enquiry | On enquiry | |
| ROJ208459/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208460/2 | MAUB | On enquiry | Board | On enquiry | On enquiry | |
| ROJ208460/3 | MAUB | On enquiry | Board | On enquiry | On enquiry | |
| ROJ208465/1 | NWI-E 450A | On enquiry | R1C | On enquiry | On enquiry | |
| ROJ208468/1 | CCIB | On enquiry | Board | On enquiry | On enquiry | |
| ROJ208813/2 | GEP2-12GB4F | Ericsson Blade System (EBS) | On enquiry | On enquiry | On enquiry | |
| ROJ208814/2 | GEP2-12GB | On enquiry | R2B | On enquiry | On enquiry | |
| ROJ208815/2 | GEP2-12GB-SAS | On enquiry | R2B | On enquiry | On enquiry | |
| ROJ208817/2 | CPUB2-24QC | On enquiry | R3B | On enquiry | On enquiry | |
| ROJ208840/3Also: TVK336145-R4B | GEP3 HD 300 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208840/5 | GEP5-400 | On enquiry | R3B or R2C | On enquiry | On enquiry | |
| ROJ208841/1 | GEP_SCD2GBS | Ericsson Blade System (EBS) | R6F | On enquiry | On enquiry | |
| ROJ208841/2 | GEP2-4-QC-HD | On enquiry | R4A | On enquiry | On enquiry | |
| ROJ208841/21 | APUB2 | On enquiry | R3A | On enquiry | On enquiry | |
| ROJ208842/5 | GEP5-1200 | On enquiry | Network Server, R1E | On enquiry | On enquiry | |
| ROJ208844/3 | GEP3-HD600 | Ericsson Blade System (EBS) | On enquiry | On enquiry | On enquiry | |
| ROJ208844/7 | GEP7 | Ericsson Blade System / BSP | On enquiry | On enquiry | On enquiry | |
| ROJ208860/5 | GEP5-10GE | On enquiry | R3A | On enquiry | On enquiry | |
| ROJ208861/2 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208864/2 | CPUB2-120C | On enquiry | R3B | On enquiry | On enquiry | |
| ROJ208864/2 | CPUB2-12QC | On enquiry | R3B | On enquiry | On enquiry | |
| ROJ208880/1 | GED-SASF | On enquiry | R1B | On enquiry | On enquiry | |
| ROJ208880/2 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208880/21 | GED-SASF | On enquiry | R1D | On enquiry | On enquiry | |
| ROJ208880/3 | GED-450GB | On enquiry | AXE 810, R1A | On enquiry | On enquiry | |
| ROJ208880/4 | GED-600GB | On enquiry | AXE 810 | On enquiry | On enquiry | |
| ROJ208882/1 | GED-DVD | On enquiry | R1C | On enquiry | On enquiry | |
| ROJ208882/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ208882/2 | GED-DVD | On enquiry | R1C | On enquiry | On enquiry | |
| ROJ208890/1 | GEA | On enquiry | R2B | On enquiry | On enquiry | |
| ROJ208890/2 | GEA | On enquiry | R1A | On enquiry | On enquiry | |
| ROJ605202/1 | On enquiry | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJ6091001/2 | EGEM2 40G | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR208002/3 R1+ | LTU16/1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR208002/3 R2+ | LTU16/1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR208003/1 | Plug In Unit / LTU 155 E/O | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR211005/1 | LTU3_12/1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR211007/1 R2+ | ETU3 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR219011/1 R1+ | FAU2 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR219014/1 R1+ | PFU3B | On enquiry | On enquiry | On enquiry | On enquiry | |
| ROJR219014/1 R2+ | PFU3B | On enquiry | On enquiry | On enquiry | On enquiry | |
| RPM2531611/5000 | 2F LC(FullAXS)-LC MM 50um 5m | On enquiry | On enquiry | On enquiry | On enquiry | |
| RPM777143/01200 | E/// RBS 6102 | On enquiry | On enquiry | On enquiry | On enquiry | |
| RYS110243/1 | On enquiry | On enquiry | Smartcard unit | On enquiry | On enquiry | |
| SN4PCGECAA | ENET 1Gb | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK1072839/1 | Expansion kit | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK1072839/2 | Expansion kit | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK1098971/1 | Dummy | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK111539/1 R1B | MOUNING SET | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK1250245/1 | SXK1250245/1; MOUNTING KIT | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK1250247/1 | SXK1250247/1 | On enquiry | On enquiry | On enquiry | On enquiry | |
| SXK1252540/1 | Rail pole bracket | On enquiry | On enquiry | On enquiry | On enquiry | |
| UKL40175/57 R2+ | RAU X 26/57 | On enquiry | On enquiry | On enquiry | On enquiry | |
| ZHY60119/1 | SAU 02 01 | On enquiry | Support alarm unit | On enquiry | On enquiry |
Cannot find a part number? Send us the number and we will identify and price it.
Ordering notes
State the subrack or magazine the board goes into, because that is what decides fit — GEM and GEM2 subracks accept different board generations. Give the board name and the full ROJ or ROA number including the revision suffix, and tell us the software release the node is running. If you are expanding rather than replacing, say how many slots are free and what is already fitted, since mixing board generations in one subrack has its own constraints.
Lifecycle and availability
Most of this hardware is end-of-sale and much of it is end-of-support. Expect new surplus and refurbished condition with CRS PLUS warranty rather than manufacturer warranty. A small number of later GEP and CPUB variants remain in circulation.
Equipment condition
New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.
New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.
Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.
Condition is confirmed in writing on every quotation before you commit to an order.
Warranty
Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.
Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.
Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.
Questions
Frequently asked questions
What is the difference between GEP2, GEP3 and GEP5?
Successive generations of the general-purpose processor blade, differing in CPU, memory and subrack support. They are not drop-in substitutes for one another — the subrack and software release both need to accept the generation you fit.
Can you supply a complete populated subrack?
Yes, subject to availability. Tell us the configuration you need and we will quote it built rather than leaving you to assemble it from separately sourced boards.
Do revision suffixes matter?
Yes. R1A and R3B of the same board can differ in supported software levels. Quote the full suffix from the label and we will match it or tell you explicitly what we are substituting.
Is this hardware still supported by Ericsson?
Largely not. That is generally why operators come to us for it — the supply route is the surplus and refurbished market, and the warranty is ours.
Related pages
Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.
This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 5 November 2026.
Need a part number from Boards, Cards & Modules?
A structured offer follows within 72 hours.