Where a buyer does not need a Huawei or Ericsson housing, the vendor-neutral cabinets from Vertiv, Delta and Eltek carry any 19-inch, −48 V DC baseband, transport or radio equipment with an embedded power system and battery strings. Vertiv's ECM3 is the closest like-for-like to an Enclosure 6150 class cabinet, Delta's OutD range runs from pole-mount enclosures to 42 kW site cabinets, and Eltek's Outdoor Type 3 and Type 4 bodies are configured with Flatpack2 rectifier systems per order. The range also covers the Vertiv NetSure M Series and NetSure D601 outdoor enclosures, the EPC48 integrated power cabinets and the Eltek Outdoor Type 2 cabinets, together with the NetSure 731 A91-S2 embedded DC power system, a 19-inch 8U subrack recently quoted from the used market. The table lists the models with dimensions, user space, climate options and power ratings from the vendors' datasheets.

How to read these part numbers

Vertiv ECM3 is sold as ECM3-14 (750 × 750 × 1685 mm, 31U) and ECM3-18 (900 × 900 × 2085 mm, 40U), each in single, double or triple bays bolted together; the embedded power is NetSure 731 — A41-S7 for 200 A or A61-S2/S3 for 300 A — with the M530S controller. NetSure X701 two-bay and three-bay enclosures are North American NEMA builds. Delta designations read ESOA or ESOF, a three-digit number and a three-letter cabinet variant — ESOA300-HAV, ESOF006-EBB — where ESOA series state capacity in kW and ESOF series mostly in amperes, and the last three letters separate cooling and compartment variants (fan, heat exchanger, DC air conditioner, thermoelectric). Delta publishes dimensions as W × H × D. Eltek Outdoor Type 3 and Type 4 are cabinet bodies: Type 3 comes in five heights (1.2–2.2 m, 21–44U, 700 mm wide), Type 4 in 1.5 m (27U) and 2.0 m (39U), and the power system fitted into them is given a configured part number of the form CTxxxxxx.nnnn. Eltek has been part of Delta Electronics since 2015.

Catalogue

Equipment reference

63 of 63 items
Part NumberModel / DesignationCompatibilityBand / InterfaceConditionLead TimeQuote
701IE4Vertiv 701IE4 outdoor power cabinet with battery cabinet, 16 kW (Asia-Pacific)Up to 5 × R48-3000e2 rectifiers; M530B controller; 230 V single-phase input700 × 700 × 2250 mm (W × D × H); ≈210 kg excl. batteries and rectifiers; 16 kW (5 × 3200 W), max 333 A DC, −53.5 V (−42 to −58 V); battery 4 × 125 A/1P, battery module space 125 × 528 × 318 mm; AC 90–300 V, 63 A/4P; Class C SPD; smoke / door / temperature sensors; IP55; rectifiers −40 to +75 °COn enquiryOn enquiry
BXSB04Also: 16U / 24U / 30U / 42U variantsVertiv Outdoor Cabinet Single, single-bay NEMA Type 4 cabinet (North America)19-inch or 23-inch EIA rails; door-mounted AC or heat exchanger; 4 / 12 / 16 in battery plinthCode format BXSB[04/3R]-[16/24/30/42]U[32/36/42]-GY-[00/04/12/16]-[cooling code]-[voltage], e.g. BXSB04-24U32-GY-12-AC020-120 = 24U, 32 in deep, 12 in riser, 2000 BTU 115 V AC unit; heights 16 / 24 / 30 / 42U; depths 32 / 36 / 42 in; riser none / 4 / 12 in or 16 in battery plinth; NEMA 4 (BXSB3R = NEMA 3R); welded aluminium frame, heavy-gauge aluminium body, solar shield and insulation; weight and temperature confirmed per quotationOn enquiryOn enquiry
CTEA0828R.401.DS3Eltek solar-powered outdoor cabinet, Flatpack2 + RectivertersUp to 8 × Flatpack2 1500 W HE + 8 (1-ph) or 12 (3-ph) Rectiverters; PV input up to 12 kW; AC out 9.6 / 14.4 kW; 48 V DC battery, 2 strings1500 × 700 × 823 mm; 150–160 kg excl. rectifiers and batteries; fan / filter cooling; IP55; −40 to +50 °COn enquiryOn enquiry
CTO31240.nnnnEltek Flatpack2 36 kW Outdoor Power System in Type 4 bodyFlatpack2 48/3000 SHE rectifiers, 36 kW / 700 A at 57.6 V DC; 3-phase 400 V input; Smartpack R controller; 8 battery breakers, 16 load MCBs, LVBD 800 A2068 × 705 × 831 mm; ≈168 kg excl. modules; 39U; dual-fan cooling (2500 W fan filter optional); IP55; −40 to +45 °COn enquiryOn enquiry
ECM3-14Also: single / double / triple bayVertiv ECM3-14 outdoor telecom enclosure with embedded NetSure 731 powerNetSure 731 A41-S7 (200 A, 7U) or A61-S2/S3 (300 A, 11U); M530S controller; 50 A rectifiers; input 80–300 V AC1685 × 750 × 750 mm single (≤250 kg); 1500 / 2250 mm wide double / triple; 31U; heat exchanger 180 W/K or air conditioner (300 W DC / 1500 W AC); 4-layer battery bay 560 × 600 × 330 mm; IP55 / IP44; −10 to +65 °C (−40 °C with heater)On enquiryOn enquiry
ECM3-18Also: single / double / triple bayVertiv ECM3-18 outdoor telecom enclosure with embedded NetSure 731 powerNetSure 731 A41-S7 (200 A) or A61-S2/S3 (300 A); M530S; up to 300 A load2085 × 900 × 900 mm single (≤280 kg); 1800 / 2700 mm wide double / triple; 40U (23U + 2-layer battery integrated variant); heat exchanger 180 W/K or air conditioner; IP55 / IP44; −10 to +65 °C (−40 °C with heater); efficiency >96 %On enquiryOn enquiry
Eltek MicrocabinetAlso: datasheet ds-2140459Eltek Microcabinet outside-plant cabinet with MicropackMicropack 48 / 24 / 12 V DC, max 1000 W; up to two battery strings 12–40 Ah; 13 RU26 × 23 × 11 in (≈660 × 584 × 280 mm); side-to-side fan filter with IP55 filter; optional battery heater pads; weight confirmed per quotationOn enquiryOn enquiry
EPC48120/1800-HA / -HBEmerson EPC48120/1800 outdoor integrated power cabinet, earlier generation (HA South / HB North)2–4 × R48-1800 hot-swap rectifiers; PSM-D21 controller; 48 V / 120 A; separate battery chamber1700 × 600 × 600 mm (H × W × D); 150 kg excl. rectifiers and battery; integrated heat exchanger; battery layer 534 × 558 × 330 mm; IP55 (excl. battery chamber); −40/−10 to +45 °C by type; AC 85–300 V, 2 × 63 A inputs; DC out 2 × 50 A + 1 × 32 A, LLVD 2 × 16 A, BLVDOn enquiryOn enquiry
EPC48120/1800-HA5Vertiv EPC48120 outdoor integrated power cabinet, South typeVertiv EPC48 series; R48-2000A3 / R48-2000e3 rectifiers (4 positions,); M521S controller; battery 2 × 63 A/1PIntegrated cabinet with battery chamber (600 × 610 × 1570 mm W × D × H); ≤110 kg; 8U user space; IP55; −10 to +45 °C; overall dimensions confirmed per quotationOn enquiryOn enquiry
EPC48120/1800-HB5Vertiv EPC48120 outdoor integrated power cabinet, North typeVertiv EPC48 series; R48-2000A3 / R48-2000e3 rectifiers (4 positions,); M521S controller; battery 2 × 63 A/1PIntegrated cabinet with battery chamber (600 × 610 × 1570 mm W × D × H, depth incl. 80 mm projection); ≤110 kg; 8U user space; heaters 630 W equipment / 630 W battery compartment (North option); IP55; −40 to +45 °COn enquiryOn enquiry
EPC48120/1800-HC5Vertiv EPC48120 outdoor split-type power cabinet, South typeVertiv EPC48 series; R48-2000A3 / R48-2000e3 rectifiers (4 positions,); M521S controller; battery 2 × 63 A/1P; separate battery cabinet600 × 610 × 840 mm (W × D × H), no battery chamber; ≤60 kg; 8U user space; IP55; −10 to +45 °COn enquiryOn enquiry
EPC48120/1800-HD5Vertiv EPC48120 outdoor split-type power cabinet, North typeVertiv EPC48 series; R48-2000A3 / R48-2000e3 rectifiers (4 positions,); M521S controller; battery 2 × 63 A/1P; separate battery cabinet600 × 610 × 840 mm (W × D × H), no battery chamber; ≤60 kg; 8U user space; IP55; −40 to +45 °COn enquiryOn enquiry
EPC48300/2900-A2Vertiv (ex-Emerson) EPC48300/2900 outdoor power cabinet, 2 mOptional Vertiv 19-inch NetSure power system, batteries and user equipment in shared 36U≤240 kg excl. modules and batteries; 2030 × 700 × 700 mm incl. base and cap; 36U flexible 19-inch space; battery layer 610 × 580 × 330 mm (W × D × H); IP55; cooling options in the series: HEX 80 / 150 W/K with 1500 W forced ventilation, air conditioner 1500 W cool / 1200 W heat (equipment) and 300 W / 600 W (battery chamber), heaters 600 / 1200 W — cooling per configurationOn enquiryOn enquiry
EPC48300/2900-F2Vertiv (ex-Emerson) EPC48300/2900 outdoor power cabinet, 2 mOptional Vertiv 19-inch NetSure power system, batteries and user equipment in shared 36U≤185 kg excl. modules and batteries; 2030 × 700 × 700 mm incl. base and cap; 36U flexible 19-inch space; battery layer 610 × 580 × 330 mm (W × D × H); IP55; cooling options in the series: HEX 80 / 150 W/K with 1500 W forced ventilation, air conditioner 1500 W cool / 1200 W heat (equipment) and 300 W / 600 W (battery chamber), heaters 600 / 1200 W — cooling per configurationOn enquiryOn enquiry
EPC48300/2900-H2Vertiv (ex-Emerson) EPC48300/2900 outdoor power cabinet, 2 mOptional Vertiv 19-inch NetSure power system, batteries and user equipment in shared 36U≤215 kg excl. modules and batteries; 2030 × 700 × 700 mm incl. base and cap; 36U flexible 19-inch space; battery layer 610 × 580 × 330 mm (W × D × H); IP55; cooling options in the series: HEX 80 / 150 W/K with 1500 W forced ventilation, air conditioner 1500 W cool / 1200 W heat (equipment) and 300 W / 600 W (battery chamber), heaters 600 / 1200 W — cooling per configurationOn enquiryOn enquiry
EPC48300/2900-M2Vertiv (ex-Emerson) EPC48300/2900 outdoor power cabinet, 2 mOptional Vertiv 19-inch NetSure power system, batteries and user equipment in shared 36U≤235 kg excl. modules and batteries; 2030 × 700 × 700 mm incl. base and cap; 36U flexible 19-inch space; battery layer 610 × 580 × 330 mm (W × D × H); IP55; cooling options in the series: HEX 80 / 150 W/K with 1500 W forced ventilation, air conditioner 1500 W cool / 1200 W heat (equipment) and 300 W / 600 W (battery chamber), heaters 600 / 1200 W — cooling per configurationOn enquiryOn enquiry
EPC48300/2900-M21Vertiv (ex-Emerson) EPC48300/2900 outdoor power cabinet, 2 mOptional Vertiv 19-inch NetSure power system, batteries and user equipment in shared 36U≤210 kg excl. modules and batteries; 2030 × 700 × 700 mm incl. base and cap; 36U flexible 19-inch space; battery layer 610 × 580 × 330 mm (W × D × H); IP55; cooling options in the series: HEX 80 / 150 W/K with 1500 W forced ventilation, air conditioner 1500 W cool / 1200 W heat (equipment) and 300 W / 600 W (battery chamber), heaters 600 / 1200 W — cooling per configurationOn enquiryOn enquiry
ESOA015-HACDelta OutD ESOA015-HAC compact outdoor power system850 W N+1; 2U shelf1350 × 765 × 814 mm; ≈100 kg excl. battery; fan cooling; 0 to +60 °C; IP confirmed per quotationOn enquiryOn enquiry
ESOA020-HCUDelta OutD ESOA020-HCU small TEC-cooled outdoor power enclosureUp to 1000 W at 200 / 230 V AC335 × 488 × 484 mm as printed; ≈57 kg; thermoelectric cooling; IP55; −40 to +46 °COn enquiryOn enquiry
ESOA050-HEADelta OutD ESOA050-HEA small outdoor power system with Li-ion battery2900 W at 200 V AC / 1500 W at 100 V AC; 48 V / 50 Ah Li-ion in 3U630 × 610 × 530 mm as printed; 84 kg (fan) to 97 kg (air conditioner); fan, HEX or AC options; IP55; −20 to +45 °COn enquiryOn enquiry
ESOA060-HBADelta OutD ESOA060-HBA wall / pole outdoor power enclosure3480 W, 2 rectifier slots286 × 550 × 600 mm as printed; ≈20 kg excl. rectifier and battery; fan; IP55; −20 to +55 °COn enquiryOn enquiry
ESOA300-CAADelta OutD ESOA300-CAA outdoor cabinet, fan + TECMax 17.4 kW; intelligent controller and adaptable PDUs2000 × 700 × 700 mm; ≈150 kg empty; fan + thermoelectric cooling; IP55; 0 to +45 °COn enquiryOn enquiry
ESOA300-HACDelta OutD ESOA300-HAC outdoor power system cabinetMax 8.7 kW; 6U power shelf; 2 banks of 200 Ah2150 × 750 × 800 mm; ≈220 kg excl. rectifiers; fan cooling; −10 to +50 °C; IP confirmed per quotationOn enquiryOn enquiry
ESOA300-HAFDelta OutD ESOA300-HAF outdoor power system cabinetMax 17.4 kW; battery space for 8 × 12 V blocks2060 × 800 × 750 mm; ≈170 kg; 16U; fan 250 W/K; IP55; −10 to +45 °COn enquiryOn enquiry
ESOA300-HAF HybridDelta OutD ESOA300-HAF Hybrid, rectifier + PV charger cabinet17.4 kW rectifier + 13.2 kW PV charger2060 × 800 × 750 mm; ≈170 kg; fan 250 W/K; IP55; 0 to +50 °C; U space confirmed per quotationOn enquiryOn enquiry
ESOA300-HAHDelta OutD ESOA300-HAH outdoor power system cabinet, fan-cooled−54 V DC default; max 20 kW; 220 V single or 380 V three-phase; 2 banks of 150 Ah2000 × 790 × 650 mm without external cooling units; ≈76 kg empty; 20U; fan cooling; −10 to +50 °C; RoHS; IP confirmed per quotationOn enquiryOn enquiry
ESOA300-HAJDelta OutD ESOA300-HAJ compact outdoor cabinetMax 12 kW; 5U power system; 96.4 % rectifier efficiency1500 × 750 × 750 mm; ≈110 kg excl. battery; fan cooling; IP55; −40 to +50 °COn enquiryOn enquiry
ESOA300-HAVDelta OutD ESOA300-HAV outdoor power system cabinet, air-conditioned or fan−54 V DC (−43 to −58 V); max 17.4 kW; rectifier model and battery confirmed per quotation2060 × 800 × 800 mm (W × H × D 800 × 2060 × 800); ≈170 kg; air conditioner 1333 / 1200 W or fan 250 W/K; IP55; −10 to +55 °COn enquiryOn enquiry
ESOA400-HCUDelta OutD ESOA400-HCU outdoor power system cabinet (North America size)Max 21.6 kW; high-density rectifiers1829 × 762 × 1041 mm (72 × 30 × 41 in); ≈276 kg; fan cooling with speed control; IP55; −40 to +50 °COn enquiryOn enquiry
ESOA400-QBADelta OutD ESOA400-QBA outdoor cabinet with separate battery compartmentMax 21 kW; rectifiers separate; TEC-cooled battery section2060 × 800 × 800 mm; ≈180 kg without rectifiers and battery; HEX 80 W/K upper + TEC battery compartment; IP55; 0 to +45 °COn enquiryOn enquiry
ESOF001-EABDelta OutD ESOF001-EAB outdoor cabinet, heat-exchanger cooledAny Delta DC or AC power system with battery backup2000 × 790 × 650 mm without external units; ≈76 kg empty; modular HEX with multi-stage fan control; −10 to +50 °C; IP confirmed per quotationOn enquiryOn enquiry
ESOF001-EACDelta OutD ESOF001-EAC compact battery / equipment cabinet2 banks of 200 Ah; power system confirmed per quotation1350 × 765 × 814 mm; ≈100 kg excl. battery; fan cooling; 0 to +60 °C; IP confirmed per quotationOn enquiryOn enquiry
ESOF006-EBBDelta OutD ESOF006-EBB outdoor cabinet with DC air conditioner−48 V DC battery-type input; −54 V DC output2100 × 800 × 800 mm; ≈190 kg; 300 W DC air conditioner; IP55; 0 to +45 °C; RoHSOn enquiryOn enquiry
ESOF009-EAADelta OutD ESOF009-EAA outdoor cabinet200 A max; rectifiers and battery confirmed per quotation2060 × 850 × 850 mm; ≈170 kg; fan 250 W/K; IP55; −10 to +55 °COn enquiryOn enquiry
ESOF010-ECVDelta OutD ESOF010-ECV single-bay 50 RU cabinet116 A max2512 × 864 × 1260 mm; ≈462 kg empty; thermosiphon heat exchanger; 50 RU; IP55; −40 to +50 °COn enquiryOn enquiry
ESOF016-ECADelta OutD ESOF016-ECA outdoor cabinet190 A max1881 × 828 × 1156 mm; ≈262 kg empty; air conditioner + fan; IP55; 0 to +46 °COn enquiryOn enquiry
ESOF024-ECBDelta OutD ESOF024-ECB outdoor cabinet600 A max1830 × 810 × 850 mm; ≈300 kg empty; TEC cooling; IP55; 0 to +46 °COn enquiryOn enquiry
ESOF028-ECBDelta OutD ESOF028-ECB outdoor cabinet54 V DC, 57 A or 46 A max2133 × 857 × 1156 mm; ≈395 kg empty; air conditioner + TEC (fan option); IP55; 0 to +46 °COn enquiryOn enquiry
ESOF030-HCUDelta OutD ESOF030-HCU large outdoor system224 A max2601 × 1932 × 1338 mm as printed plus 4 in plinth; ≈1107 kg excl. batteries; thermosiphon HEX; IP55; −40 to +46 °COn enquiryOn enquiry
ESOF075-ECUDelta OutD ESOF075-ECU compact TEC-cooled outdoor power enclosure−48 V DC; 116 A max; 110–120 V AC single-phase input568 × 329 × 452 mm (H × W × D); ≈42.5 kg; thermoelectric cooling; IP55; −40 to +46 °COn enquiryOn enquiry
ESOF200-ECUDelta OutD ESOF200-ECU outdoor power system cabinet (North America size)−48 V DC telecom; up to 160 A at nominal single-phase input1829 × 762 × 1041 mm (72 × 30 × 41 in); ≈256 kg excl. battery; fan cooling; IP55; −20 to +50 °COn enquiryOn enquiry
F2020029Vertiv NetSure X701 multi-bay outdoor enclosure, two-bay (North America)Factory-integrated NetSure 512 (−48 / −58 V DC); eSure 40 A / 2000 W rectifiers; 3 VRLA strings ≤210 Ah86 × 68 × 54 in (≈2184 × 1727 × 1372 mm); ≈590 kg; 43 RU; closed-loop heat exchangers 6000 W + 2800 W; aluminium; −40 to +46 °C; UL 2416, UL 50EOn enquiryOn enquiry
F2020030Vertiv NetSure X701 multi-bay outdoor enclosure, three-bay (North America)As two-bay74 × 102 × 54 in as printed; ≈748 kg; 76 RU; two 6000 W equipment chambers + 2800 W power chamber; −40 to +46 °C; UL 2416, UL 50EOn enquiryOn enquiry
NetSure 731 A91-S2Vertiv NetSure 731 A91-S2 embedded −48 V DC power system, 19-inch 8UVertiv −48 V DC site power; supplied used-original as a complete setEmbedded subrack, not an enclosure; 483 × 400 × 352 mm (W × D × H), 8U; ≤25 kg excl. rectifiers; 540 A (60 A modules) or 450 A (50 A modules); AC 1 × 100 A/4P, Class C SPD, 80–300 V AC; battery 4 × 125 A/1P; LLVD 3 × 63 A + 3 × 32 A + 2 × 16 A; BLVD 2 × 63 A + 2 × 32 A + 2 × 16 A; DC SPD ≥20 kA; −40 to +65 °C (derated above 45 °C); sister codes A91-S1 (540 A, M830B) and A91-S3 (450 A, M830B)On enquiryOn enquiry
NetSure M20Vertiv NetSure M Series outdoor enclosure, 20UHouses NetSure 5100 / 531 / 7100 / 731 DC systems (6–31.5 kW); 19-inch1050 × 730 × 750 mm; 55 kg empty; 20U; battery space up to 16U; one thermal zone; fan filter overpressure up to 5200 W (260 W/K), air conditioner 520–2000 W (AC or −48 V DC, DC up to 2800 W), HEX 65–150 W/K, heaters 250 / 800 W; IP55 (IP65 with overpressure fan filter); −33 to +50 °COn enquiryOn enquiry
NetSure M35Vertiv NetSure M Series outdoor enclosure, 35UHouses NetSure 5100 / 531 / 7100 / 731 DC systems (6–31.5 kW); 19-inch1674 × 730 × 750 mm; 75 kg empty; 35U; battery space up to 32U; one or two thermal zones; fan filter overpressure up to 5200 W (260 W/K), air conditioner 520–2000 W (AC or −48 V DC, DC up to 2800 W), HEX 65–150 W/K, heaters 250 / 800 W; 200 W TEC option for battery compartment (up to two −48 V lead-acid strings); IP55 (IP65 option); −33 to +50 °COn enquiryOn enquiry
NetSure M44Vertiv NetSure M Series outdoor enclosure, 44UHouses NetSure 5100 / 531 / 7100 / 731 DC systems (6–31.5 kW); 19-inch2074 × 730 × 750 mm; 95 kg empty; 44U; battery space up to 32U; one or two thermal zones; fan filter overpressure up to 5200 W (260 W/K), air conditioner 520–2000 W (AC or −48 V DC, DC up to 2800 W), HEX 65–150 W/K, heaters 250 / 800 W; IP55 (IP65 option); −33 to +50 °COn enquiryOn enquiry
OutD 1200VDelta OutD V Series outdoor cabinet, 22 HU (1.2 m)Delta DC power systems; optional Delta CellD battery backup1200 × 708 × 720 mm (H × W × D); 70 kg; 22 HU; hybrid thermal options AV + AC, HEX + AV or AV + TEC; IP54 standard, IP55 optional; −33 to +50 °C; IEC/EN 60950, EN 300 386On enquiryOn enquiry
OutD 1800VDelta OutD V Series outdoor cabinet, 35 HU (1.8 m)Delta DC power systems; optional Delta CellD battery backup1800 × 708 × 720 mm (H × W × D); 120 kg; 35 HU; hybrid thermal options AV + AC, HEX + AV or AV + TEC; IP54 standard, IP55 optional; −33 to +50 °C; IEC/EN 60950, EN 300 386On enquiryOn enquiry
OutD 700VDelta OutD V Series outdoor cabinet, 13 HU (0.8 m)Delta DC power systems; optional Delta CellD DC / AC battery backup800 × 600 × 500 mm (H × W × D); 35 kg; 13 HU; hybrid thermal options AV + AC, HEX + AV or AV + TEC; IP54 standard, IP55 optional; −33 to +50 °C; IEC/EN 60950, EN 300 386On enquiryOn enquiry
Outdoor Type 2 15UEltek Outdoor Cabinet Type 2, 15U, aluminium (floor / wall / pole)19-inch rails, 12U usable + 3U DIN-rail AC section; Eltek DC power and telecom / industrial equipment; up to 2 battery trays (≤150 kg each)743 × 586 × 580 mm fan/filter (28.4 kg) or 743 × 586 × 790 mm air-con (48.4 kg); fan filter 700 W (F5 filter) or air conditioner 570 W (520 W option); optional 400 W heater; IP55, NEMA 3R, UL 50; 1.5 mm aluminium skin, galvanised frame, RAL 7035On enquiryOn enquiry
Outdoor Type 2 22UEltek Outdoor Cabinet Type 2, 22U, aluminium (floor / wall / pole)19-inch rails, 19U usable + 3U DIN-rail AC section; up to 2 battery trays (≤150 kg each)1047.5 × 586 × 580 mm fan/filter (32.4 kg) or 1047.5 × 586 × 790 mm air-con (52.4 kg); fan filter 700 W or air conditioner 570 W; optional 400 W heater, 152 mm plinth; IP55, NEMA 3R, UL 50On enquiryOn enquiry
Outdoor Type 3Also: 1.2 / 1.5 / 1.8 / 2.0 / 2.2 m; single, dual, two-chamberEltek Outdoor Type 3 cabinet body, galvanised steel (aluminium optional)Eltek Flatpack2 / Smartpack power systems and 19-inch equipment; up to 4 battery trays (≤260 kg per tray)1200–2200 × 700 × 770 mm; 21 / 28 / 34 / 39 / 44U; 69–105 kg excl. cooling; fan filter 2000 W, air conditioner 520–2000 W, heat exchanger 100 W/K (+202 mm depth) or hybrids up to 3000 W + 120 W/K; IP55, NEMA 3ROn enquiryOn enquiry
Outdoor Type 3 dual bayEltek Outdoor Type 3 cabinet, dual bay (thermally separated left / right bays)Eltek Flatpack2 / Smartpack power systems and 19-inch equipment; right bay battery shelf 700 × 516 × 180 mm2200 × 1462 × 901 mm (H × W × D); left and right bays thermally separated; IP55, NEMA 3R; cooling per Type 3 options (fan filter 2000 W, AC 0.52–2 kW, HEX 100 W/K); weight confirmed per quotationOn enquiryOn enquiry
Outdoor Type 3 dual chamberEltek Outdoor Type 3 cabinet, dual chamber (fan-cooled equipment zone over air-conditioned battery zone)Upper chamber 10U 19-inch for rectifiers and telecom equipment; lower chamber batteries700 mm wide × 770 mm deep body (Type 3 range 1.2–2.2 m high); upper zone fan filter 700 W; lower zone small air conditioner with double-layer insulation; IP55, NEMA 3R; height and weight for this build confirmed per quotationOn enquiryOn enquiry
Outdoor Type 4 1.5 mEltek Outdoor Type 4 cabinet, 1.5 mEltek power systems configured in (CTxxxxxx.nnnn); battery trays ≤280 kg1456 × 705 × 772 mm without thermal unit; 61 kg (+27 kg thermal unit); 27U; fan filter 1700 W single / 2500 W dual at ΔT 10 °C; up to two 500 W heaters; IP55On enquiryOn enquiry
Outdoor Type 4 2.0 mEltek Outdoor Type 4 cabinet, 2.0 mAs Type 4 1.5 m2068 × 705 × 772 mm without thermal unit; 67 kg (+37 kg thermal unit); 39U; fan filter 1700 / 2500 W; two 500 W heaters; IP55On enquiryOn enquiry
U57-15000-215LFZAVertiv NetSure D601 outdoor power cabinet, 21 kW, battery bay fan-filterVertiv NetSure D601 outdoor power cabinet; NetSure 7100 DC system; lithium-ion battery chamber (modules up to 250 Ah each, up to 1500 Ah)2140 × 900 × 1430 mm; NetSure 7100 up to 21 kW; battery bay fan filter >45 W/K; up to 582 kg excl. batteries and solar shelves; 27U battery shelving; power bay fan filter >55 W/K; IP55; −10 to +45 °C (DC power equipment)On enquiryOn enquiry
U57-15000-215LZAVertiv NetSure D601 outdoor power cabinet, 21 kW, battery bay air-conditionedVertiv NetSure D601 outdoor power cabinet; NetSure 7100 DC system; lithium-ion battery chamber (modules up to 250 Ah each, up to 1500 Ah)2140 × 900 × 1320 mm; NetSure 7100 up to 21 kW; battery bay air conditioner 520 / 600 W; up to 582 kg excl. batteries and solar shelves; 27U battery shelving; power bay fan filter >55 W/K; IP55; −10 to +45 °C (DC power equipment)On enquiryOn enquiry
U57-15000-216ESFZAVertiv NetSure D601 outdoor power cabinet, 31.5 kW, battery bay fan-filter, enhanced securityVertiv NetSure D601 outdoor power cabinet; NetSure 7100 DC system; lithium-ion battery chamber (modules up to 250 Ah each, up to 1500 Ah)2140 × 900 × 1430 mm; NetSure 7100 up to 31.5 kW; battery bay fan filter >45 W/K; up to 582 kg excl. batteries and solar shelves; 27U battery shelving; power bay fan filter >55 W/K; IP55; −10 to +45 °C (DC power equipment); enhanced-security buildOn enquiryOn enquiry
U57-15000-216ESZAVertiv NetSure D601 outdoor power cabinet, 31.5 kW, battery bay air-conditioned, enhanced securityVertiv NetSure D601 outdoor power cabinet; NetSure 7100 DC system; lithium-ion battery chamber (modules up to 250 Ah each, up to 1500 Ah)2140 × 900 × 1320 mm; NetSure 7100 up to 31.5 kW; battery bay air conditioner 520 / 600 W; up to 582 kg excl. batteries and solar shelves; 27U battery shelving; power bay fan filter >55 W/K; IP55; −10 to +45 °C (DC power equipment); enhanced-security buildOn enquiryOn enquiry
U57-15000-216LFZAVertiv NetSure D601 outdoor power cabinet, 31.5 kW, battery bay fan-filterVertiv NetSure D601 outdoor power cabinet; NetSure 7100 DC system; lithium-ion battery chamber (modules up to 250 Ah each, up to 1500 Ah)2140 × 900 × 1430 mm; NetSure 7100 up to 31.5 kW; battery bay fan filter >45 W/K; up to 582 kg excl. batteries and solar shelves; 27U battery shelving; power bay fan filter >55 W/K; IP55; −10 to +45 °C (DC power equipment)On enquiryOn enquiry
U57-15000-216LZAVertiv NetSure D601 outdoor power cabinet, 31.5 kW, battery bay air-conditionedVertiv NetSure D601 outdoor power cabinet; NetSure 7100 DC system; lithium-ion battery chamber (modules up to 250 Ah each, up to 1500 Ah)2140 × 900 × 1320 mm; NetSure 7100 up to 31.5 kW; battery bay air conditioner 520 / 600 W; up to 582 kg excl. batteries and solar shelves; 27U battery shelving; power bay fan filter >55 W/K; IP55; −10 to +45 °C (DC power equipment)On enquiryOn enquiry

Ordering notes

Give the equipment to be housed in U and its heat load in watts, the DC load in amperes, the battery autonomy, the AC supply and the ambient range; the climate option is chosen from those — ECM3 heat exchanger 180 W/K or 1500 W air conditioner, Eltek Type 4 fan filter 1700 or 2500 W, Delta HAV air conditioner 1200–1333 W — and the rectifier count follows the load. Weights published by all three vendors exclude rectifier modules and batteries, so specify both for freight. Certificates and country approvals for the destination are requested per configuration because ratings differ by climate option. No list price is published; quotations are per cabinet with the configuration itemised — housing, climate unit, rectifier frame, modules, monitoring, batteries, plinth — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.

Lifecycle and availability

Vertiv ECM3, NetSure X701 and the Outdoor Cabinet Single are current catalogue items; the ECM3 product pages are partner-restricted and availability is confirmed per quotation. Delta OutD series pages are live for more than thirty ESOA / ESOF variants. Eltek Outdoor Type 3, Type 4 and the Flatpack2 36 kW outdoor system remain live products under the Eltek brand within Delta. None of the three vendors publishes end-of-life dates on these pages.

Choosing between a branded ODM cabinet and an OEM original

A vendor-neutral cabinet suits a site where the radio vendor may change, where the buyer wants a single cabinet standard across Huawei, Ericsson and Nokia sites, or where a used OEM enclosure is not acceptable to the operator. What it does not provide is the OEM's site monitoring integration: Vertiv M530S and Eltek Smartpack controllers expose dry contacts and SNMP rather than the Huawei or Ericsson management protocol, so alarm mapping is confirmed at design stage. Where the site is an existing OEM footprint, the plinth dimensions decide — ECM3-14 is 750 × 750 mm, ECM3-18 900 × 900 mm, Eltek Type 3 700 × 770 mm, Delta ESOA300 800 × 800 mm.

Equipment condition

New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.

New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.

Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.

Condition is confirmed in writing on every quotation before you commit to an order.

Warranty

Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.

Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.

Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.

Refurbished stock — how it is graded and what ships

New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.

Cosmetic grade.Is the housing new?
Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
Test coverage.Is it fully working?
Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
What ships with the cabinet.With plinth, keys and internal fittings?
The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
Warranty on used stock.What warranty?
Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
Firmware state.Is the firmware in English, and is it locked?
The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
Licence state (OLT chassis and control boards).What about licences on a used OLT?
Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.

Questions

Frequently asked questions

Do the ECM3, OutD and Type 3 cabinets come with the power system?

ECM3 ships with the embedded NetSure 731 power frame and controller, with rectifier modules specified per order. Delta OutD cabinets are sold with Delta rectifier shelves sized to the series capacity, rectifiers specified separately. Eltek Type 3 and Type 4 are bodies into which a Flatpack2 or Smartpack system is configured and given its own part number. In every case the quotation lists the frame, the modules fitted and the batteries as separate lines.

What is included with a cabinet — rectifiers, batteries, climate unit, plinth?

Manufacturer weights are almost always quoted without rectifier modules and batteries, and dealer listings often say only "equipped cabinet". Every quotation from CRS PLUS itemises what ships: the housing, base frame or plinth, climate unit (heat exchanger, air conditioner or ventilation), rectifier frame and the number of modules fitted, monitoring unit, busbars, breakers and surge protection, battery trays and whether batteries are supplied. Ask for the packing list before comparing prices between sources.

Which climate variant suits a hot-climate site?

Heat-exchanger cabinets are sealed and suit most sites; direct-ventilation battery bays carry a lower ingress rating and suit cleaner, cooler locations; air-conditioned variants are specified where ambient temperature or solar load would otherwise shorten battery life. State the site's ambient range and whether the cabinet is in the sun and the quotation will say which variant is proposed and why.

Can I house another vendor's baseband or radios in the cabinet?

Site enclosures with open 19-inch space (Ericsson 6130/6140/6150, Vertiv ECM3, Eltek Type 3/4, Delta OutD, Nokia ACOA/ACOB) accept any 19-inch, −48 V DC equipment; what must be checked is the DC breaker count and rating, cable entry, heat load against the climate unit and the alarm interface. Platform-specific housings (Huawei APM30H/TMC11H, ZTE BS8900 cabinets, Nokia AMOB/AMOD) are built around their own baseband and are quoted with that platform.

How are cabinets shipped and how long does it take?

Cabinets are crated or palletised and normally move by sea because of volume; air freight is quoted where the schedule demands it. Dispatch time and transit time are stated separately on the quotation. Lithium batteries are dangerous goods in transit, so cabinets are usually shipped without batteries unless DG-compliant freight is arranged.

What warranty applies, and what does it cover on used cabinets?

Warranty terms are stated per line item on the quotation, for new and refurbished cabinets alike. On refurbished units the warranty covers functional failure of the climate unit, power frame and monitoring under normal use; the period, exclusions and return procedure are set out in writing before you commit to an order.

Will the footprint fit my existing plinth?

Footprints differ between generations even within one vendor — an RBS 6102 is 1300 × 700 mm and an Enclosure 6150 800 × 700 mm; a Huawei ICC330 is 650 × 650 mm and an ICC710 900 × 950 mm. Send the existing plinth or base-frame dimensions and the anchor pattern with the enquiry and the quotation will confirm fit or propose an adapter frame.

Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.

This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 7 November 2026.

Need a part number from Outdoor Cabinets & Enclosures?

A structured offer follows within 72 hours.

Sending a full specification or a BOQ? Use the full RFQ form.