Ericsson · Outdoor Cabinets & Enclosures

Ericsson outdoor enclosures — Enclosure 6150, 6140, 6130 and the RBS 6000 cabinets

The Enclosure 6150 is one of the most requested Ericsson cabinets, typically supplied complete with heat exchanger, nine-slot rectifier frame and monitoring unit, and it is bought alongside the smaller 6140 and 6130, the US-specification 6160, the B158 / B160 battery cabinets and the previous-generation RBS 6101 / 6102 macro cabinets that the enclosures replaced in new shipments. This page lists the family with dimensions, user space, climate and power ratings from Ericsson's product descriptions, the dealer product numbers under which the cabinets trade (300/BFM 107 206/1 for the 6150), and what a complete build includes.

How to read these part numbers

RBS 61xx are outdoor macro cabinets of the RBS 6000 generation — 6101 single bay (700 × 700 × 1450 mm), 6102 dual bay (1300 × 700 × 1450 mm) — with the radios and baseband inside the cabinet. RBS 62xx are indoor and are not listed here. Enclosure 61x0 is the newer site-enclosure family that houses baseband, transport and power and feeds remote radios: 6130 is the smallest, with no internal battery; 6140 is mid-size (8–21U); 6150 the largest, 20 kW class with two battery strings; 6160 the UL-listed North American build. Enclosure B1xx (B158, B160, B174) are battery cabinets. Within the 6150, "8 kW ST" and "20 kW ST" give the rectifier power to load, "Full 19-inch Rack" is the 24U variant, HEX is the standard heat exchanger and HEX/AirCon adds an air conditioner on the battery compartment. Dealer product numbers run in the BFM 107 xxx/1 series; "AGO" appears on dealer listings for equipped cabinets and is not defined in any Ericsson source, so the configuration label is checked rather than inferred.

Catalogue

Equipment reference

27 of 27 items
Part NumberModel / DesignationCompatibilityBand / InterfaceConditionLead TimeQuote
300/BFM 107 206/1Also: BFM107206/1Enclosure 6150 equipped cabinet (AGO), dealer product numberEnclosure 6150 family; configuration per label — 8 or 20 kW, HEX or AirCon, PSU countSupplied new, complete: power-compartment frame, rack brackets, battery compartment and fixing brackets, grounding busbar, cable entry, cabin LED, door contact, HEX with dual DC fans, 9-slot rectifier frame, monitoring unit, AC SPD; modules and batteries separateOn enquiryOn enquiry
All-in-One Outdoor Enclosure (2014)Ericsson All-in-One Outdoor Enclosure for RBS 6000, high-capacity single-footprint siteUp to 8 digital units, 18 radios and 4 MINI-LINK hops; standalone up to 8 DU + 12 radio units; main-remote up to 16 DU + 18 RRUsFootprint 700 × 700 mm (<0.5 m²); targeted at mild-to-warm climates; height, weight and climate rating confirmed per quotationOn enquiryOn enquiry
BBS 2116 V2Ericsson BBS 2116 V2 outdoor battery backup cabinet (main + optional extension cabinet)Recommended for RBS 2116 V2 and RBS 3116; also RBS 2106 / 2106i / 2106 V3 / 2107 and RBS 3106 / 3107 / 3101; max 2 RBS cabinets per BBS1400 × 648 × 815 mm excl. installation / base frame; <135 kg excl. batteries (24 V/100 Ah set 77 kg; 48 V/100 Ah or 24 V/200 Ah set <154 kg each); IP55; optional heating and active cooling; output +24 V or −48 V DC nominal; capacity 200 (100) to 600 (300) Ah main cabinet, up to 1200 (600) Ah with extension cabinet, 100 Ah steps (10 h rate; brackets = 48 V); −33 to +50 °COn enquiryOn enquiry
BMK 905 42/2Also: BMK90542/2PBC (Power and Battery Cabinet) for Ericsson RBS 2000 micro base stationsEricsson RBS site battery backupSame width and length as the micro RBS, with a modified rear sun-shield for battery volume; AC mains input (screw terminal 3 × 2.5 mm²); AC/DC converter plus replaceable DC-backup batteries; outputs 2 × regulated +24 V DC (RBS 1 / RBS 2) and 2 × regulated −48 V DC (AAU, link equipment), separately fused; recharge <24 h after full discharge; optional enhanced lightning protection; dimensions, weight and Ah confirmed per quotationOn enquiryOn enquiry
Combined Climate Unit (RBS 2106)Ericsson door-mounted combined climate unit for RBS 2106 outdoor cabinetRBS 2106 outdoor cabinet door (one per cabinet)1250 × 1050 × 250 mm; 105 kg; max 2300 W AC (230 V 50 Hz) / 450 W DC; heater starts below −5 °C internal start-up temperatureOn enquiryOn enquiry
Enclosure 6130Also: BMK 905 077/1 (6130 AC 21 kW HEX)Ericsson Enclosure 6130, smallest ERS ground enclosure, no internal batteryBaseband, power supply and backhaul; 8U / 10U; batteries in a separate B174 enclosure950 × 650 × 820 mm (1100 mm with base), ≈130 kg (a 2021 sheet gives 1051 × 650 × 700 mm, 124 kg); −33 to +45 °C; AC 85–300 V, max 70 A 1/2-phase or 35 A 3-phase; −48 V DC out; IP confirmed per quotationOn enquiryOn enquiry
Enclosure 6140Also: 300/BFM 107 205/1 (6140 AGO)Ericsson Enclosure 6140, AC or DC configurationUp to 18 multi-standard remote radios; 21U (DC build) or 10U with batteries (AC build)1607 × 700 × 752 mm incl. 150 mm base; 150–190 kg excl. equipment and batteries; HEX −33 to +50 °C, heater optional; 240 V AC or −48 V DC; up to 8 kW (200 A), 3 kW rectifiers; AC build holds 12–210 Ah; IP55On enquiryOn enquiry
Enclosure 6150 20 kW HEX/AirConEricsson Enclosure 6150, 20 kW with air-conditioned battery compartment (active cooling)ERS baseband, transport, third-party equipment; up to 21 external radios over DC and CPRI2050 × 800 × 700 mm incl. base frame; 240–276 kg by source; 9U; equipment HEX 2350 W −33 to +50 °C; battery air conditioner 300 W −33 to +55 °C, heater optional; 9 × 3000 W PSU slots, 27 kW installed; IP55On enquiryOn enquiry
Enclosure 6150 20 kW STEricsson Enclosure 6150, 20 kW standard build, heat exchangerAs 8 kW ST; multi-radio / multi-baseband sites; up to 21 remote radios2050 × 800 × 940 mm incl. base and HEX; 240 kg; 9U; HEX 2300 W; 20 kW to load + 7 kW to batteries, up to 9 × 3 kW PSU; 2–4 × 200 A battery breakers; 2 strings ≤210 Ah; −33 to +45 °COn enquiryOn enquiry
Enclosure 6150 8 kW STEricsson Enclosure 6150, 8 kW standard build, heat exchangerRBS 6000 / ERS baseband (DUS, DUG, DUW, Baseband 5216 / 6630), transport, third-party 19-inch equipment; internal battery1920 × 800 × 700 mm; 233 kg; 13U; HEX, 2300 W heat dissipation; AC 200–250 V 1/2/3-phase; −48 V DC, 8 kW to load + 4 kW to batteries, up to 4 PSU; 2 strings ≤210 Ah; −33 to +45 °COn enquiryOn enquiry
Enclosure 6150 Full 19-inch RackEricsson Enclosure 6150, full 19-inch rack buildBaseband, transport and external equipment racking; batteries external1770 × 800 × 940 mm; 223 kg; 24U; 2700 W heat dissipation; 20 kW class −48 V DC; −33 to +45 °COn enquiryOn enquiry
Enclosure 6160Ericsson Enclosure 6160, UL-listed North American buildPairs with Enclosure B160 battery cabinet; 19 RU; up to 9 rectifier modules≈1600 × 650 × 660 mm incl. 100 mm base (63 × 25.6 × 26 in); ≈145 kg; 208–240 V AC, 500 A main breaker; up to 33 kVA; heat exchanger −33 to +50 °C, dual 500 W heaters; UL 62368-1 / UL 50E / GR-63On enquiryOn enquiry
Enclosure 6330Ericsson Enclosure 6330, small ERS enclosure5U for ERS radios / transport850 × 650 × 425 mm; 50 kg; climate and IP confirmed per quotationOn enquiryOn enquiry
Enclosure 6340Ericsson Enclosure 6340, small ERS enclosure2U equipment space575 × 700 × 300 mm; 40 kg; climate and IP confirmed per quotationOn enquiryOn enquiry
Enclosure B158Ericsson Enclosure B158 outdoor battery cabinet for Enclosure 6150Enclosure 6150; 19-inch and 23-inch battery units, 3 to 7 units over two banks (BKB 902 71/1 48 V / 100 Ah referenced)≈265 kg for the 6150 + B158 set incl. base frame; cabinet dimensions confirmed per quotationOn enquiryOn enquiry
Enclosure B160Also: BMF 107 221/1Ericsson Enclosure B160 outdoor battery cabinetBattery backup for Enclosure 6160; 3 strings of 100–210 Ah lead-acid; 19 RU≈1600 × 650 × 700 mm incl. base; ≈134 kg; fan / filter ventilation; UL 62368-1 / UL 50E / GR-63On enquiryOn enquiry
Enclosure B174Ericsson Enclosure B174 outdoor battery enclosureERS cabinets, named as the battery enclosure for Enclosure 6130Dimensions and capacity confirmed per quotationOn enquiryOn enquiry
Heat Exchanger Climate Unit (RBS 2106)Ericsson door-mounted heat-exchanger climate unit for RBS 2106 outdoor cabinetRBS 2106 outdoor cabinet door; alternative to the combined climate unit1250 × 1050 × 250 mm; 97 kg; max 2100 W AC (230 V 50 Hz); 600–650 W DC; heater for cold start (below −5 / +5 °C)On enquiryOn enquiry
RBS 2106Ericsson RBS 2106 outdoor GSM macro cabinet (variants RBS 2106, 2106i, 2106 V3)Up to 6 dTRU (12 TRX), GSM 800 / 900 / 1800 / 1900Footprint 1300 × 710 mm; height confirmed per quotation; 500–660 kg by climate unit and battery fit (RBS 2106: 520 kg excl. / 660 kg incl. batteries with combined climate unit, 500 / 640 kg with heat-exchanger climate unit; RBS 2106 V3 up to 806 kg incl. batteries); door-mounted combined climate unit or heat-exchanger climate unit; average heat load 3000 W; IP55 (IEC 60529); AC only, 200–250 V nominal (180–275 V operating), 1-, 2- or 3-phase, 50/60 Hz; PSU 4 × 1200 W (V3: 4 × 1500 W); −33 to +45 °C (base RBS 2106 with HEX climate unit −33 to +40 °C); internal battery backup ≈1 h (full) / 0.5 h (half); 19-inch TM space 445 mm high × 267–280 mm deepOn enquiryOn enquiry
RBS 2107Ericsson RBS 2107 outdoor GSM macro cabinet, 6 TRXUp to 3 dTRU (6 TRX), omni or up to 3 sectors; optional internal batteries or external BBS 9500 via DC filter; optional 250 mm base frame 709/BYB 415 01/08Footprint 1000 × 710 mm, door protrudes 216 mm; height confirmed per quotation; 390 kg fully equipped excl. batteries, 425 kg incl. batteries; door with climate unit; IP55 (IEC 60529); 200–250 V AC nominal (180–275 V operating), 1-, 2- or 3-phase; PSU 3 × 1200 W (3600 W); power consumption 1700 W; average heat load 1600 W; internal battery backup 4 h (full) / 2.5 h (half); BFU 1 × 200 A; −33 to +45 °COn enquiryOn enquiry
RBS 2302Ericsson RBS 2302 micro RBS, outdoor wall / pole / mast mount, 2 TRXGSM micro cell, up to 6 TRX per micro cell by cascading; internal battery; optional external PBC535 × 408 × 160 mm (210 mm deep with sector antenna, 607 mm high with omni antenna); cabinet 18 kg incl. internal battery, 31 kg with base and bracket; IP55 (IEC 529) and UL 50 Type 3R; 200–250 V AC 50 Hz or 100–127 V AC 60 Hz; <140 VA normal, <500 VA with heater; internal battery ≥3 min; −33 to +45 °C (+55 °C with fan unit)On enquiryOn enquiry
RBS 2308Ericsson RBS 2308 micro RBS, outdoor wall / pole / mast mount, 4 TRXGSM micro cell; optional external PBC power and battery cabinet610 × 433 × 224 mm basic, 742 × 433 × 270 mm with fan unit and RXBP; 41 kg; IP55 (IEC 60529) and UL 50 Type 3R; AC 100–127 V nominal (90–140 V) or −48 V DC (−40.5 to −57 V); −33 to +45 °C without fan, to +55 °C with fan (AC build)On enquiryOn enquiry
RBS 3106Ericsson RBS 3106 outdoor WCDMA cabinetUp to 9 radio units; internal batteries 100–200 Ah or external BBU 9500 / BBS 85001630 × 1300 × 710 mm; 630 kg typical, up to 850 kg; forced convection + heat exchanger; 200–433 V AC or −48 V DC; IP55; −33 to +45 °COn enquiryOn enquiry
RBS 3107Ericsson RBS 3107 outdoor WCDMA macro cabinetOptional internal batteries (4 blocks on internal shelf) or external battery backup via DC filter; BBS 2116 V2 listed as compatibleMax 350 kg excl. batteries; 3-phase + PEN 346/200–433/250 V AC factory setting (other AC configurations possible); cables entered from below; mounts on base frame with M16 bolts; dimensions confirmed per quotationOn enquiryOn enquiry
RBS 6101Ericsson RBS 6101 outdoor macro cabinet, single bayRBS 6000 radio and baseband units (GSM / WCDMA / LTE) in one weather-tight cabinet; batteries external1450 × 700 × 700 mm; 180 kg fully equipped excl. batteries; climate unit; 110–250 V AC or −48 V DC; −33 to +50 °COn enquiryOn enquiry
RBS 6102Also: 302/BFM 901 292 (RBS 6102 AGO)Ericsson RBS 6102 outdoor macro cabinet, dual bayUp to 12 radio units, baseband in main bay, integrated climate, AC / DC power, battery bay1450 × 1300 × 700 mm; 330–390 kg fully equipped excl. batteries by source; 110–250 V AC or −48 V DC; −33 to +50 °C; NEMA 3R variant existsOn enquiryOn enquiry
SDC 901 32/1Also: SDC90132/1TMR 9302 transmission outdoor cabinetEricsson transmission / MINI-LINK site equipmentDimensions, climate and IP confirmed per quotationOn enquiryOn enquiry

Ordering notes

Name the enclosure and the variant — 6150 8 kW, 20 kW, HEX or HEX/AirCon, full rack — and whether it is required equipped or as a housing. State the AC supply (single, two or three phase), the number of rectifier modules to be fitted (the 6150 carries up to nine 3 kW PSU slots), the battery strings and capacity, and the equipment to be housed in U. Give the plinth or base-frame dimensions of the existing site where the cabinet is a replacement: the 6150 footprint is 800 × 700 mm and does not match an RBS 6102 plinth. Condition is stated per quotation — new, new surplus or refurbished with the cosmetic grade — and where a destination does not admit used network equipment we quote new. No list price is published; quotations are per cabinet with the configuration itemised — housing, climate unit, rectifier frame, modules, monitoring, batteries, plinth — and are prepared landed to the destination city where requested, with packed dimensions and weight stated for the freight line.

Lifecycle and availability

Ericsson's product summary states that the ERS enclosures 6130, 6140, 6150 and 6160 replace RBS 6000 cabinets in new shipments; the Enclosure 6150 HEX/AirCon has been marketed as the current multi-purpose active-cooling cabinet since 2018. RBS 6101 and 6102 are therefore secondary-market items, supplied refurbished and graded. RBS 2106 and 3106 are GSM and WCDMA-era cabinets supplied for site expansion or swap-out only. No official end-of-sale notice was found for any model; status is confirmed per quotation.

Enclosure 6150 — what a complete cabinet includes

A complete Enclosure 6150 as quoted by CRS PLUS is the power-compartment main frame, the rack mounting brackets, the battery-compartment box and battery fixing brackets, grounding busbar, waterproof cable entry, cabin LED light and door contact, the heat exchanger with dual DC fans, the nine-slot rectifier frame, the power monitoring unit and the AC surge protector. Rectifier modules and batteries are quoted as separate lines so that the buyer chooses the count and the chemistry. Where a dealer substitutes the rectifier frame or ships without the monitoring unit the quotation says so.

The 8 kW ST build gives 13U of user space with up to four rectifiers; the 20 kW ST gives 9U with up to nine; the full 19-inch rack build gives 24U and is used where the cabinet is mainly racking baseband and transport. All three are −48 V DC with two battery strings of up to 210 Ah each, except the full-rack build which takes batteries externally.

RBS 6102 or Enclosure 6150 when replacing a site cabinet

The RBS 6102 is the older dual-bay outdoor macro: 1300 × 700 × 1450 mm, about 330–390 kg fully equipped, with up to twelve radio units and the baseband inside. The Enclosure 6150 is the current site enclosure: 800 × 700 mm footprint, 223–276 kg, holding baseband, 20 kW DC power and batteries and feeding up to 21 remote radios over DC and CPRI. They are not interchangeable footprints and they assume different radio architectures — in-cabinet radios against main-remote — so the choice follows the site design rather than the cabinet price. Send the current configuration and the quotation sets out both options.

Equipment condition

New — factory-sealed, supplied through the manufacturer's own channel or a qualified distributor, with full manufacturer warranty.

New surplus — unused factory stock, original packaging where available, sourced from decommissioned projects or distributor inventory. Manufacturer warranty may have lapsed; CRS PLUS warranty applies.

Refurbished / tested — previously deployed equipment, cleaned, firmware-checked and functionally tested against the manufacturer's specification before shipment. CRS PLUS warranty applies.

Condition is confirmed in writing on every quotation before you commit to an order.

Warranty

Warranty terms vary by item, by condition and by the supplier the equipment is sourced from. They are stated in writing on the quotation, per line item, before you commit to an order.

Where equipment is supplied new through the manufacturer's own channel, the manufacturer's warranty applies and is passed to you.

Send us the part numbers you need and we will confirm warranty terms alongside availability, condition, lead time and price.

Refurbished stock — how it is graded and what ships

New and refurbished units are quoted side by side. For refurbished stock, the quotation answers the questions buyers ask first, in the order they ask them.

Cosmetic grade.Is the housing new?
Every refurbished unit is graded A, B or C and the grade is written on the quotation. Grade A: housing free of marks visible at arm's length, no discolouration, original labels intact. Grade B: light scuffing or minor marks, no cracks, labels legible. Grade C: visible wear or discolouration, functionally identical to A and B, offered only where the buyer has accepted it. Where an enclosure has been replaced with a new housing the quotation says so; a re-cased unit is never described as new.
Test coverage.Is it fully working?
Cabinets and enclosures are inspected and function-tested before dispatch: door seals and gaskets, locks and hinges, the heat exchanger or air conditioner run under power, fans and heaters, the rectifier shelf and monitoring unit powered up, busbars, breakers and surge protection checked, and the housing inspected for corrosion and impact damage. The scope of the test is stated on the quotation.
What ships with the cabinet.With plinth, keys and internal fittings?
The quotation lists exactly what ships: base frame or plinth, keys, rack mounting brackets, battery trays or fixing brackets, grounding busbar, cable-entry plates, cabin lighting and door contact, the climate unit, the rectifier frame and monitoring unit where fitted, and whether rectifier modules and batteries are included. Units are crated or palletised for sea or air freight and the packed dimensions and weight are stated for freight quotation.
Warranty on used stock.What warranty?
Warranty on refurbished equipment covers functional failure under normal use and is stated per line item on the quotation — the period, what it covers and how a return is handled — before you commit to an order.
Firmware state.Is the firmware in English, and is it locked?
The language of the shipped firmware and whether a unit is carrier-branded or carrier-locked is declared per lot. Where English firmware is required it is confirmed on the unit before dispatch, not assumed from the model number. Locked or operator-branded stock is declared as such and never described as open.
Licence state (OLT chassis and control boards).What about licences on a used OLT?
Second-hand OLT chassis and control boards are quoted with their licence and software state as received, stated on the quotation. CRS PLUS does not represent used chassis as carrying transferable licences; software licensing remains between the buyer and the manufacturer or integrator, and we recommend confirming the licensing position before relying on a used chassis for a live rollout.

Questions

Frequently asked questions

What is the difference between Enclosure 6150 HEX and HEX/AirCon?

Both cool the equipment compartment with a 2350 W heat exchanger rated −33 to +50 °C. HEX/AirCon adds a 300 W DC-fan air conditioner on the battery compartment, rated to +55 °C, which suits hot sites where batteries would otherwise age early. The configuration label on the cabinet states which one a used unit is.

Does a used 6150 or 6140 come with rectifiers and batteries?

Not by default — listings such as 300/BFM 107 206/1 say only "equipped cabinet". Get the PSU count, battery trays and the HEX or AirCon unit in writing. The 6130 has no internal battery space and pairs with a B174 battery enclosure.

What is included with a cabinet — rectifiers, batteries, climate unit, plinth?

Manufacturer weights are almost always quoted without rectifier modules and batteries, and dealer listings often say only "equipped cabinet". Every quotation from CRS PLUS itemises what ships: the housing, base frame or plinth, climate unit (heat exchanger, air conditioner or ventilation), rectifier frame and the number of modules fitted, monitoring unit, busbars, breakers and surge protection, battery trays and whether batteries are supplied. Ask for the packing list before comparing prices between sources.

Which climate variant suits a hot-climate site?

Heat-exchanger cabinets are sealed and suit most sites; direct-ventilation battery bays carry a lower ingress rating and suit cleaner, cooler locations; air-conditioned variants are specified where ambient temperature or solar load would otherwise shorten battery life. State the site's ambient range and whether the cabinet is in the sun and the quotation will say which variant is proposed and why.

Can I house another vendor's baseband or radios in the cabinet?

Site enclosures with open 19-inch space (Ericsson 6130/6140/6150, Vertiv ECM3, Eltek Type 3/4, Delta OutD, Nokia ACOA/ACOB) accept any 19-inch, −48 V DC equipment; what must be checked is the DC breaker count and rating, cable entry, heat load against the climate unit and the alarm interface. Platform-specific housings (Huawei APM30H/TMC11H, ZTE BS8900 cabinets, Nokia AMOB/AMOD) are built around their own baseband and are quoted with that platform.

How are cabinets shipped and how long does it take?

Cabinets are crated or palletised and normally move by sea because of volume; air freight is quoted where the schedule demands it. Dispatch time and transit time are stated separately on the quotation. Lithium batteries are dangerous goods in transit, so cabinets are usually shipped without batteries unless DG-compliant freight is arranged.

What warranty applies, and what does it cover on used cabinets?

Warranty terms are stated per line item on the quotation, for new and refurbished cabinets alike. On refurbished units the warranty covers functional failure of the climate unit, power frame and monitoring under normal use; the period, exclusions and return procedure are set out in writing before you commit to an order.

Will the footprint fit my existing plinth?

Footprints differ between generations even within one vendor — an RBS 6102 is 1300 × 700 mm and an Enclosure 6150 800 × 700 mm; a Huawei ICC330 is 650 × 650 mm and an ICC710 900 × 950 mm. Send the existing plinth or base-frame dimensions and the anchor pattern with the enquiry and the quotation will confirm fit or propose an adapter frame.

Manufacturer names, product names and part numbers are the property of their respective owners and are used here for identification purposes only. CRS PLUS sources these products through its qualified supplier base and holds no distributor, reseller or agency appointment from any manufacturer listed.

This catalogue is compiled from our supplier network's available inventory and from manufacturer product documentation, and is reviewed monthly. Listing does not indicate stock held by CRS PLUS — availability, condition and lead time are confirmed per enquiry. Last reviewed: 7 November 2026.

Need a part number from Outdoor Cabinets & Enclosures?

A structured offer follows within 72 hours.

Sending a full specification or a BOQ? Use the full RFQ form.